AIAM 2026
8th International Conference on Artificial Intelligence
and Advanced Manufacturing
Frankfurt · 29–31 October 2026

An Intelligent Neuro-Phenotyping Information System

Multimodal Data Fusion, EEG Acquisition, and Privacy-Preserving Architecture for Visual Snow Syndrome
Péter Szigeti1,2  ·  László Bakó2
1 Doctoral School of Applied Informatics and Applied Mathematics, Óbuda University, Budapest
2 Department of Electrical Engineering, Sapientia Hungarian University of Transylvania, Târgu Mureș
Neurological & Clinical Context

Visual snow syndrome: a central neurological perceptual disorder

Pan-field visual static

Continuous dynamic noise across the entire visual field, day and night

Palinopsia

Persistent afterimages and trailing of moving objects

Photopsia & entoptic phenomena

Spontaneous flashes and enhanced perception of intraocular structures

Tinnitus

A frequent auditory comorbidity: a persistent tone or hiss

A neurological disorder with normal ocular examinations; proposed mechanisms include cortical hyperexcitability and thalamocortical dysrhythmia. Phenotype characterised across 1,100 patients Puledda et al. 2020; clinical expertise remains concentrated in tertiary centres.

Problem statement

Three barriers to objective measurement

"Like TV static…" ? no number

Qualitative self-report

Symptoms are reported verbally and cannot be mapped to a quantitative neurophysiological measure.

Clinic A 7 / 10 Clinic B mild moderate severe ≠

Inter-centre variability

Ordinal rating scales differ between clinics, so severity reports are not comparable across sites.

Research 128-ch Lab-confined Consumer EEG Proprietary silos unified clinical record

Inaccessible neurophysiology

Clinical EEG requires specialised hospital visits; home-grade consumer headsets exist, but use proprietary silos rather than reproducible clinical pipelines.

Aim: an objective, shareable record created at home and reviewable by a specialist anywhere.

Prior work

Electrophysiological evidence in visual snow is early-stage

C4 · Level 1 · System Context

Connecting home neuro-phenotyping to clinical evaluation under zero knowledge

C4 · Level 2 · Container Architecture

Four containers; keys never reach the relay

C4 · Level 3 · Component Architecture

The phone captures; the browsers encrypt and analyse

Step 1 · Psychophysical matching C3.1

Patients calibrate an overlay against their percept

45%
60%
50%
Interactive demonstration

A 110-field symptom vector in seven groups

Each square is one field. No patient exhibits every phenomenon, so the vector is sparse.

Visual static 7
Entoptic phenomena 18
Photic phenomena 31
Distortions 19
Field & contrast loss 13
Tinnitus 7
Tremor & associated 15
QR code for openvisual.org/schema

Serialised in the open Open Visual Symptom (OVS) schema, interoperable with Open mHealth.
openvisual.org/schema

Step 2 · EEG acquisition C3.2

Hardware-agnostic acquisition on two consumer headsets

BrainBit 2

Dry electrodes at O1, O2, T7, T8 (occipital and temporal) · 250 Hz

Muse S Athena

Electrodes at AF7, AF8, TP9, TP10 (frontal and temporoparietal) · 256 Hz

Both stream four channels over Bluetooth Low Energy. The open-source BrainFlow library and vendor SDKs form one acquisition layer, so the analysis runs unchanged on any supported headset.

The full-rate raw recording is retained on the device as the record of truth. The code path is device-agnostic; feature thresholds are montage-specific.

Step 3 · Recording protocol C3.3

Five scripted one-minute scenarios of rising arousal

Scripted, fixed order

On-screen prompts are word-for-word identical in every run, so the induction is the one thing that does not vary.

Silent counting

Subtraction is done silently: counting aloud adds jaw-muscle activity to the temporal channels.

Marked segments

Each scenario's start and end travel with the raw export, so the portal re-analyses the same windows.

Never ends on stress

A 30 s eyes-closed wind-down closes every session; it is recorded but not scored.

5.5 minutes per session. In the fixed order, eye state and time on task change together with arousal. The app also records an alternating eyes-closed/eyes-open block (5 × 60 s).

Step 4 · Spectral re-analysis C3.6

Wavelet analysis resolves rhythm power over time

① RAW EEG
② 128-VOICE MORLET WAVELET TRANSFORM

Long wavelets resolve slow rhythms; short wavelets resolve fast rhythms.

Aperiodic correction: the 1/f background is fitted and removed before band powers and the individual alpha frequency (IAF, peak in 7–14 Hz) are read.

③ TIME–FREQUENCY MAP (SCALOGRAM)
eyes open
eyes closed
eyes open
alpha, eyes closed
gamma
beta
alpha
theta
delta
slow ↓ · fast ↑time →

Illustration of how the map looks.

Three-level rule: the alpha/gamma ratio, alpha suppression and IAF rate each session Normal, Elevated or High. Confirming the thresholds requires more recordings from VSS patients.

④ BAND POWER · ILLUSTRATIVE VALUES

Possible observation: visual snow persists with the eyes closed, as static and light and dark flicker, so eyes-closed rest may show visual activity in the spectrum that is absent without VSS, in line with the raised eyes-closed alpha reported by Hsiao, Puledda et al. 2026. Confirming this requires more recordings from VSS patients.

Step 5 · Multimodal fusion C3.7

Cohort analytics fuse four feature blocks per patient

Feature selection

Categorical selectors are excluded, and fields left at default by every cohort member carry no variance and are dropped.

Standardisation

Each feature is z-scored, so no single measure dominates.

Unsupervised analysis

Principal component analysis and k-means clustering find the main axes of variation, the intended route to characterising phenotypes.

Step 6 · Zero-knowledge sharing C3.4 / C3.5

Only the designated specialist can decrypt the case

Standard web cryptography

Uses native browser W3C Web Crypto APIs (standard PBKDF2 & AES-GCM). Zero custom or experimental crypto.

Zero-knowledge cloud relay

The server routes and lists cases but cannot read one: case and EEG files are stored only as ciphertext, and it never receives keys.

Decryption & revocation

Specialist decrypts locally using out-of-band password. Consent withdrawal immediately deletes cloud ciphertext.

QR code for visualsnow.app
Clinical portal
visualsnow.app
Evaluation

Five data sets, synthetic and real, test the pipeline

Test environment: Intel Core i7 laptop (4 cores, 32 GB RAM), Windows 11, headless Chromium driven by Playwright.

No trained model, by design: labelled clinical data are not yet available and every output must remain explainable; recordings are therefore compared individually with a healthy reference group.

Result 1 · Performance in the browser

Analysis runs in the browser; the server only stores and relays

Patient portal
Opens the app exportCreates a one-time passwordEncrypts the case
4 ms

to evaluate an uploaded 20-week log

< 0.2 s

to encrypt it for sharing

4 KB

a 20-week diary, compressed

→ciphertext
Thin server
StoreRelayDelete
Ciphertext

is all it stores; no analysis runs here

2.2 MB

for ten encrypted 20-week cases

Patient

owns the raw data; the server cannot read it

→ciphertext
Specialist portal
Decrypts locallyWavelet re-analysis (JavaScript or WebAssembly)Fusion, trends, cohort analytics
0.14 s

to decrypt and load one case

1.4 s

for ten 20-week cases

0.2 s

EEG re-analysis per minute of recording

The heavy work runs on the users' own devices: the server stays small and cheap, and the raw data stay with the patient.

Result 2 · Headset recordings

No VSS-specific marker yet in the first recordings

Each recording is compared with 10 healthy people from a public data set: does it fall outside their normal range?

0 of 8

recordings fell outside the normal range on the alpha/gamma balance. The other markers showed no consistent pattern.

Five candidate markers

Alpha/gamma balanceslow resting rhythm against fast activity
Background slopehow fast power falls from slow to fast rhythms
Alpha peak frequencyspeed of the dominant resting rhythm, in Hz
Rhythm couplingwhether slow waves pace fast activity
Left–right synchronyhow in step the two sides of the visual cortex are

Few samples: 8 recordings from 2 people, with muscle noise in every recording. The system is built to keep collecting recordings and testing these markers as more patients take part.

Result 3 · Cohort analytics

Synthetic personas test the group-analysis pipeline

How the personas were built

Pattern map of the 10 personas

The patterns were built in, so this tests the group-analysis pipeline, not a clinical hypothesis.

Discussion

How our results compare with earlier studies

Topic
They found
We found
Verdict
Fast code in the browser
Jangda 2019 · Yan 2021 · De Macedo 2022
Slower than native code; gain over JavaScript varies
1.1× faster than JavaScript, at the modest end
Consistent
Keeping work in the browser
Rosa 2026
11.3× faster end-to-end than a server pipeline
Analysis and encryption fully client-side; encryption 91.9 ms
Consistent
Affordable headsets
Cannard 2021
Valid spectral measures; reliable alpha power
Comparison with clinical EEG planned
To be tested
Alpha in visual snow
Klein 2024
No occipital alpha difference; reduced temporal and parietal alpha
Alpha/gamma ratio indistinguishable from controls in every session
Agrees (different measure)
Fast rhythms in visual snow
Hepschke 2022 · Hsiao 2026
Direction of fast-rhythm change inconsistent
No consistent shift either way
Open question

None of these comparisons is a clinical claim.

Exploratory · Digital twin proof-of-concept

An exploratory digital twin simulates candidate mechanisms

Mechanism model

Sleep-debt cortisol drives glutamate/GABA balance, modulated by the thalamocortical dysrhythmia ratio, in a spiking network of 80 V1 and 40 thalamic-reticular units.

Deterministic control

Typed commands (sleep, stress, lamotrigine dosing) drive the simulation; the mapping to the rendered percept is hand-tuned and not yet validated.

Contained language model

A local model only writes the first-person description; generated text never sets a simulation parameter.

Conclusions & Contributions

Private, cross-device telemonitoring is technically feasible

OVS

Multimodal record

110

symptom fields fused with EEG features from the raw recording, in one OVS case record

Private by design

AES-256

end-to-end: cases are encrypted in the browser, and the server stores only ciphertext

1 layer

Device-agnostic, deterministic

< 10−7

WebAssembly vs JavaScript; one acquisition layer for two headsets

Analytics-ready

10

synthetic personas test trends, PCA and k-means; the digital twin is exploratory

Take-home: keep the raw recording as the record of truth, and re-derive every feature from it.

Limitations

Limitations and next steps

Current limitations

Gamma bandmuscle and device noise flagged, not yet removed
Pilot scalea small group so far; more participants are needed
Synthetic cohortten personas; weakly separated clusters
Single platformone desktop host, one browser engine
Digital twinhand-tuned parameter mapping

These results verify system behaviour, not clinical performance.

Next steps

1More people and headsets
2Comparison with clinical EEG
3Phantom checks, muscle-artefact removal
4Benchmarks on mobile hardware
5Phenotype-matched flicker
6Registered study of profile stability
Questions & resources

Thank you

Péter Szigeti  ·  László Bakó

QR: visualsnow.app
Clinical portal
visualsnow.app
QR: Google Play
Android app
Google Play
QR: App Store
iPhone app
App Store
QR: symptom format
OVS schema
openvisual.org/schema
QR: project site
Project & research
visualsnow.pages.dev

Supported by the Domus Hungarica group homeland research scholarship (2026) of the Hungarian Academy of Sciences and by the Visual Snow Initiative. Software developed by Entropy Vector Group, Târgu Mureș, as part of doctoral research at Óbuda University.

Szigeti & Bakó · AIAM 2026
 ·  ? help

All slides

Keyboard

→ SpaceNext slide ←Previous slide VVisual snow effect on / off FFullscreen on / off OOverview of all slides Home EndFirst slide / Thank-you slide EscClose this panel