Continuous dynamic noise across the entire visual field, day and night
Persistent afterimages and trailing of moving objects
Spontaneous flashes and enhanced perception of intraocular structures
A frequent auditory comorbidity: a persistent tone or hiss
A neurological disorder with normal ocular examinations; proposed mechanisms include cortical hyperexcitability and thalamocortical dysrhythmia. Phenotype characterised across 1,100 patients Puledda et al. 2020; clinical expertise remains concentrated in tertiary centres.
Symptoms are reported verbally and cannot be mapped to a quantitative neurophysiological measure.
Ordinal rating scales differ between clinics, so severity reports are not comparable across sites.
Clinical EEG requires specialised hospital visits; home-grade consumer headsets exist, but use proprietary silos rather than reproducible clinical pipelines.
Aim: an objective, shareable record created at home and reviewable by a specialist anywhere.
Each square is one field. No patient exhibits every phenomenon, so the vector is sparse.
Serialised in the open Open Visual Symptom (OVS) schema, interoperable with Open mHealth.
openvisual.org/schema
Dry electrodes at O1, O2, T7, T8 (occipital and temporal) · 250 Hz
Electrodes at AF7, AF8, TP9, TP10 (frontal and temporoparietal) · 256 Hz
Both stream four channels over Bluetooth Low Energy. The open-source BrainFlow library and vendor SDKs form one acquisition layer, so the analysis runs unchanged on any supported headset.
The full-rate raw recording is retained on the device as the record of truth. The code path is device-agnostic; feature thresholds are montage-specific.
On-screen prompts are word-for-word identical in every run, so the induction is the one thing that does not vary.
Subtraction is done silently: counting aloud adds jaw-muscle activity to the temporal channels.
Each scenario's start and end travel with the raw export, so the portal re-analyses the same windows.
A 30 s eyes-closed wind-down closes every session; it is recorded but not scored.
5.5 minutes per session. In the fixed order, eye state and time on task change together with arousal. The app also records an alternating eyes-closed/eyes-open block (5 × 60 s).
Long wavelets resolve slow rhythms; short wavelets resolve fast rhythms.
Aperiodic correction: the 1/f background is fitted and removed before band powers and the individual alpha frequency (IAF, peak in 7–14 Hz) are read.
Illustration of how the map looks.
Three-level rule: the alpha/gamma ratio, alpha suppression and IAF rate each session Normal, Elevated or High. Confirming the thresholds requires more recordings from VSS patients.
Possible observation: visual snow persists with the eyes closed, as static and light and dark flicker, so eyes-closed rest may show visual activity in the spectrum that is absent without VSS, in line with the raised eyes-closed alpha reported by Hsiao, Puledda et al. 2026. Confirming this requires more recordings from VSS patients.
Categorical selectors are excluded, and fields left at default by every cohort member carry no variance and are dropped.
Each feature is z-scored, so no single measure dominates.
Principal component analysis and k-means clustering find the main axes of variation, the intended route to characterising phenotypes.
Uses native browser W3C Web Crypto APIs (standard PBKDF2 & AES-GCM). Zero custom or experimental crypto.
The server routes and lists cases but cannot read one: case and EEG files are stored only as ciphertext, and it never receives keys.
Specialist decrypts locally using out-of-band password. Consent withdrawal immediately deletes cloud ciphertext.
Test environment: Intel Core i7 laptop (4 cores, 32 GB RAM), Windows 11, headless Chromium driven by Playwright.
No trained model, by design: labelled clinical data are not yet available and every output must remain explainable; recordings are therefore compared individually with a healthy reference group.
to evaluate an uploaded 20-week log
to encrypt it for sharing
a 20-week diary, compressed
is all it stores; no analysis runs here
for ten encrypted 20-week cases
owns the raw data; the server cannot read it
to decrypt and load one case
for ten 20-week cases
EEG re-analysis per minute of recording
The heavy work runs on the users' own devices: the server stays small and cheap, and the raw data stay with the patient.
Each recording is compared with 10 healthy people from a public data set: does it fall outside their normal range?
recordings fell outside the normal range on the alpha/gamma balance. The other markers showed no consistent pattern.
Few samples: 8 recordings from 2 people, with muscle noise in every recording. The system is built to keep collecting recordings and testing these markers as more patients take part.
The patterns were built in, so this tests the group-analysis pipeline, not a clinical hypothesis.
None of these comparisons is a clinical claim.
Sleep-debt cortisol drives glutamate/GABA balance, modulated by the thalamocortical dysrhythmia ratio, in a spiking network of 80 V1 and 40 thalamic-reticular units.
Typed commands (sleep, stress, lamotrigine dosing) drive the simulation; the mapping to the rendered percept is hand-tuned and not yet validated.
A local model only writes the first-person description; generated text never sets a simulation parameter.
symptom fields fused with EEG features from the raw recording, in one OVS case record
end-to-end: cases are encrypted in the browser, and the server stores only ciphertext
WebAssembly vs JavaScript; one acquisition layer for two headsets
synthetic personas test trends, PCA and k-means; the digital twin is exploratory
Take-home: keep the raw recording as the record of truth, and re-derive every feature from it.
These results verify system behaviour, not clinical performance.
Péter Szigeti · László Bakó
Supported by the Domus Hungarica group homeland research scholarship (2026) of the Hungarian Academy of Sciences and by the Visual Snow Initiative. Software developed by Entropy Vector Group, Târgu Mureș, as part of doctoral research at Óbuda University.